Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add filters








Year range
1.
Chinese Journal of Medical Education Research ; (12): 291-295, 2020.
Article in Chinese | WPRIM | ID: wpr-865794

ABSTRACT

High-altitude physiology is a basic and core discipline of high-altitude medicine and also a required course for undergraduates majoring in high-altitude medicine. At present, high-altitude physiology teaching mainly adopts the traditional teaching mode, with a monotony teaching method. MOOC is a newly emerging online course model with advanced educational concepts. Under the background of the current military reform, the MOOC combined with the traditional teaching mode in high-altitude teaching can not only comprehensively improve the teaching quality and learning ability, but also effectively enhance the competency of students in high-altitude military medicine.

2.
Chinese Critical Care Medicine ; (12): 1535-1537, 2019.
Article in Chinese | WPRIM | ID: wpr-800023

ABSTRACT

Objective@#To investigate the value of pulse indicator continuous cardiac output (PiCCO) monitoring in the treatment management of patients with severe heart failure.@*Methods@#Sixty patients of severe heart failure admitted to intensive care unit (ICU) of Fujian Provincial Hospital from August 2017 to February 2019 were enrolled, and they were divided into control group and treatment group according to random number table method, with 30 in each group. The treatment group used bedside PiCCO to carry out minimally invasive hemodynamics monitoring, according to the monitoring data target guidance for vasoactive drugs and liquid management. The control group was based only on traditional electrocardiogram (ECG) monitoring and lung sound, urine volume of vasoactive drugs and liquid management. The changes of cardiac index (CI), global end diastolic volume index (GEDVI), extravascular lung water index (EVLWI), systemic vascular resistance index (SVRI), invasive mean arterial pressure (MAP) and central venous pressure (CVP) were observed before and 72 hours after treatment in the treatment group. The 7-day total effective rate, the length of ICU stay and 28-day mortality were compared between the two groups.@*Results@#Compared with before treatment, CI and MAP in the treatment group were significantly increased after treatment [CI (mL·s-1·m-2): 53.34±16.67 vs. 35.01±13.34, MAP (mmHg, 1 mmHg = 0.133 kPa): 72.6±10.6 vs. 62.5±10.3, both P < 0.05], GEDVI, EVLWI, SVRI, CVP were significantly decreased [GEDVI (mL/m2): 760.3±90.2 vs. 960.2±110.3, EVLWI (mL/kg): 6.5±1.3 vs. 12.5±6.2, SVRI (kPa·s·L-1·m-2): 297.3±35.1 vs. 434.1±58.8, CVP (mmHg): 10.1±2.6 vs. 12.2±3.4, all P < 0.05]. Compared with the control group, the 7-day total effective rate of the treatment group was significantly higher (90.0% vs. 80.0%), the length of ICU stay was significantly shorter (days: 8.2±4.5 vs. 10.3±2.5), and the 28-day mortality was significantly lower, with statistically significant difference (all P < 0.05).@*Conclusion@#PiCCO monitoring is a goal-oriented treatment management for patients with severe heart failure, which is helpful to individualized accurate treatment, shorten the length of ICU stay and improve short-term prognosis.

3.
Chinese Critical Care Medicine ; (12): 1231-1235, 2019.
Article in Chinese | WPRIM | ID: wpr-796505

ABSTRACT

Objective@#To evaluate the difference and correlation between continuous non-invasive arterial pressure (CNAP) monitor and pulse indicated continuous cardiac output (PiCCO) monitor on determination of hemodynamic parameters in mechanically ventilated critically ill patients, and to assess the feasibility of non-invasive monitoring of hemodynamics with CNAP.@*Methods@#A prospective observation self-control study was conducted.The critically ill patients with mechanical ventilation who needed hemodynamics monitoring, and admitted to the fourth department of intensive care unit (ICU) of Fujian Provincial Hospital from June 2018 to March 2019 were enrolled. PiCCO catheter were inserted immediately after admission, the hemodynamic indexes were measured by thermodilution method, and mean arterial pressure (MAPPiCCO), cardiac index (CIPiCCO), pulse pressure variation rate (PPVPiCCO) and systemic vascular resistance index (SVRIPiCCO) were obtained at 0 hour and 24 hours respectively. Meanwhile, the above indexes (MAPCNAP, CICNAP, PPVCNAP and SVRICNAP) were measured with CNAP. All measurements were repeated thrice and average values were reported. The differences in above parameters between the two methods were evaluated. Pearson test was used for the correlation analysis and Bland-Altman analysis method was used for consistency test.@*Results@#Thirty-eight patients were enrolled into this study. One patient died within 24 hours was excluded, 2 patients were excluded due to withdrawing treatment within 24 hours, 2 patients were excluded because of atrial fibrillation, and 1 patient's data was lost due to technical problems. Thus, data from 32 patients were available for final analysis. There were 12 females and 20 males, aging 26-84 years old with the mean of (66.8±19.1) years old, body mass index (BMI) of (23.7±3.9) kg/m2, acute physiology and chronic health evaluationⅡ (APACHEⅡ) score of 19.5±5.3, sepsis-related organ failure assessment (SOFA) score of 9.7±4.1. There were no significant differences in CI or PPV between CNAP and PiCCO groups [CI (mL·s-1·m-2): 59.8±12.6 vs. 58.5±14.2, PPV: (14.7±6.8)% vs. (14.0±6.8)%, both P > 0.05]. MAP and SVRI measured by CNAP were significantly higher than those measured by PiCCO [MAP (mmHg, 1 mmHg = 0.133 kPa): 65.6±9.4 vs. 60.1±9.2, SVRI (kPa·s·L-1·m-2): 206.2±53.9 vs. 179.5±57.8, both P < 0.01]. The correlation analysis showed that MAP, CI, PPV and SVRI measured by the two methods were significantly positively correlated (r value was 0.624, 0.864, 0.835 and 0.655 respectively, all P < 0.05). Bland-Altman analysis showed that CNAP and PiCCO had a good consistency for the measurement of CI and PPV, the average differences were 1.2 mL·s-1·m-2 and 0.5% respectively, while the 95% confidence interval (95%CI) were -12.8-15.3 mL·s-1·m-2 and -7.1%-8.2% respectively. However, the consistency of MAP and SVRI measured by those two methods was poor, the average differences were 5.5 mmHg and 26.8 kPa·s·L-1·m-2 respectively, while the 95%CI was -10.4-21.3 mmHg and -64.5-118.0 kPa·s·L-1·m-2 respectively.@*Conclusion@#CNAP was comparable with PiCCO when monitoring CI and PPV in mechanically ventilated critically ill patients; while the results of MAP and SVRI might be inaccurate, which should be interpreted correctly and carefully.

4.
Chinese Critical Care Medicine ; (12): 1359-1363, 2019.
Article in Chinese | WPRIM | ID: wpr-791081

ABSTRACT

Objective To evaluate the difference and correlation between continuous non-invasive arterial pressure (CNAP) monitor and pulse indicated continuous cardiac output (PiCCO) monitor on determination of hemodynamic parameters in mechanically ventilated critically ill patients, and to assess the feasibility of non-invasive monitoring of hemodynamics with CNAP. Methods A prospective observation self-control study was conducted. The critically ill patients with mechanical ventilation who needed hemodynamics monitoring, and admitted to the fourth department of intensive care unit (ICU) of Fujian Provincial Hospital from June 2018 to March 2019 were enrolled. PiCCO catheter were inserted immediately after admission, the hemodynamic indexes were measured by thermodilution method, and mean arterial pressure (MAPPiCCO), cardiac index (CIPiCCO), pulse pressure variation rate (PPVPiCCO) and systemic vascular resistance index (SVRIPiCCO) were obtained at 0 hour and 24 hours respectively. Meanwhile, the above indexes (MAPCNAP, CICNAP, PPVCNAP and SVRICNAP) were measured with CNAP. All measurements were repeated thrice and average values were reported. The differences in above parameters between the two methods were evaluated. Pearson test was used for the correlation analysis and Bland-Altman analysis method was used for consistency test. Results Thirty-eight patients were enrolled into this study. One patient died within 24 hours was excluded, 2 patients were excluded due to withdrawing treatment within 24 hours, 2 patients were excluded because of atrial fibrillation, and 1 patient's data was lost due to technical problems. Thus, data from 32 patients were available for final analysis. There were 12 females and 20 males, aging 26-84 years old with the mean of (66.8±19.1) years old, body mass index (BMI) of (23.7±3.9) kg/m2, acute physiology and chronic health evaluationⅡ (APACHEⅡ) score of 19.5±5.3, sepsis-related organ failure assessment (SOFA) score of 9.7±4.1. There were no significant differences in CI or PPV between CNAP and PiCCO groups [CI (mL·s-1·m-2): 59.8±12.6 vs. 58.5±14.2, PPV: (14.7±6.8)% vs. (14.0±6.8)%, both P > 0.05]. MAP and SVRI measured by CNAP were significantly higher than those measured by PiCCO [MAP (mmHg, 1 mmHg = 0.133 kPa):65.6±9.4 vs. 60.1±9.2, SVRI (kPa·s·L-1·m-2): 206.2±53.9 vs. 179.5±57.8, both P < 0.01]. The correlation analysis showed that MAP, CI, PPV and SVRI measured by the two methods were significantly positively correlated (r value was 0.624, 0.864, 0.835 and 0.655 respectively, all P < 0.05). Bland-Altman analysis showed that CNAP and PiCCO had a good consistency for the measurement of CI and PPV, the average differences were 1.2 mL·s-1·m-2 and 0.5% respectively, while the 95% confidence interval (95%CI) were -12.8-15.3 mL·s-1·m-2 and -7.1%-8.2% respectively. However, the consistency of MAP and SVRI measured by those two methods was poor, the average differences were 5.5 mmHg and 26.8 kPa·s·L-1·m-2 respectively, while the 95%CI was -10.4-21.3 mmHg and -64.5-118.0 kPa·s·L-1·m-2 respectively. Conclusion CNAP was comparable with PiCCO when monitoring CI and PPV in mechanically ventilated critically ill patients; while the results of MAP and SVRI might be inaccurate, which should be interpreted correctly and carefully.

5.
Chinese Critical Care Medicine ; (12): 1231-1235, 2019.
Article in Chinese | WPRIM | ID: wpr-791057

ABSTRACT

Objective To evaluate the difference and correlation between continuous non-invasive arterial pressure (CNAP) monitor and pulse indicated continuous cardiac output (PiCCO) monitor on determination of hemodynamic parameters in mechanically ventilated critically ill patients, and to assess the feasibility of non-invasive monitoring of hemodynamics with CNAP. Methods A prospective observation self-control study was conducted. The critically ill patients with mechanical ventilation who needed hemodynamics monitoring, and admitted to the fourth department of intensive care unit (ICU) of Fujian Provincial Hospital from June 2018 to March 2019 were enrolled. PiCCO catheter were inserted immediately after admission, the hemodynamic indexes were measured by thermodilution method, and mean arterial pressure (MAPPiCCO), cardiac index (CIPiCCO), pulse pressure variation rate (PPVPiCCO) and systemic vascular resistance index (SVRIPiCCO) were obtained at 0 hour and 24 hours respectively. Meanwhile, the above indexes (MAPCNAP, CICNAP, PPVCNAP and SVRICNAP) were measured with CNAP. All measurements were repeated thrice and average values were reported. The differences in above parameters between the two methods were evaluated. Pearson test was used for the correlation analysis and Bland-Altman analysis method was used for consistency test. Results Thirty-eight patients were enrolled into this study. One patient died within 24 hours was excluded, 2 patients were excluded due to withdrawing treatment within 24 hours, 2 patients were excluded because of atrial fibrillation, and 1 patient's data was lost due to technical problems. Thus, data from 32 patients were available for final analysis. There were 12 females and 20 males, aging 26-84 years old with the mean of (66.8±19.1) years old, body mass index (BMI) of (23.7±3.9) kg/m2, acute physiology and chronic health evaluationⅡ (APACHEⅡ) score of 19.5±5.3, sepsis-related organ failure assessment (SOFA) score of 9.7±4.1. There were no significant differences in CI or PPV between CNAP and PiCCO groups [CI (mL·s-1·m-2): 59.8±12.6 vs. 58.5±14.2, PPV: (14.7±6.8)% vs. (14.0±6.8)%, both P > 0.05]. MAP and SVRI measured by CNAP were significantly higher than those measured by PiCCO [MAP (mmHg, 1 mmHg = 0.133 kPa):65.6±9.4 vs. 60.1±9.2, SVRI (kPa·s·L-1·m-2): 206.2±53.9 vs. 179.5±57.8, both P < 0.01]. The correlation analysis showed that MAP, CI, PPV and SVRI measured by the two methods were significantly positively correlated (r value was 0.624, 0.864, 0.835 and 0.655 respectively, all P < 0.05). Bland-Altman analysis showed that CNAP and PiCCO had a good consistency for the measurement of CI and PPV, the average differences were 1.2 mL·s-1·m-2 and 0.5% respectively, while the 95% confidence interval (95%CI) were -12.8-15.3 mL·s-1·m-2 and -7.1%-8.2% respectively. However, the consistency of MAP and SVRI measured by those two methods was poor, the average differences were 5.5 mmHg and 26.8 kPa·s·L-1·m-2 respectively, while the 95%CI was -10.4-21.3 mmHg and -64.5-118.0 kPa·s·L-1·m-2 respectively. Conclusion CNAP was comparable with PiCCO when monitoring CI and PPV in mechanically ventilated critically ill patients; while the results of MAP and SVRI might be inaccurate, which should be interpreted correctly and carefully.

6.
Chinese Critical Care Medicine ; (12): 1535-1537, 2019.
Article in Chinese | WPRIM | ID: wpr-824239

ABSTRACT

Objective To investigate the value of pulse indicator continuous cardiac output (PiCCO) monitoring in the treatment management of patients with severe heart failure. Methods Sixty patients of severe heart failure admitted to intensive care unit (ICU) of Fujian Provincial Hospital from August 2017 to February 2019 were enrolled, and they were divided into control group and treatment group according to random number table method, with 30 in each group. The treatment group used bedside PiCCO to carry out minimally invasive hemodynamics monitoring, according to the monitoring data target guidance for vasoactive drugs and liquid management. The control group was based only on traditional electrocardiogram (ECG) monitoring and lung sound, urine volume of vasoactive drugs and liquid management. The changes of cardiac index (CI), global end diastolic volume index (GEDVI), extravascular lung water index (EVLWI), systemic vascular resistance index (SVRI), invasive mean arterial pressure (MAP) and central venous pressure (CVP) were observed before and 72 hours after treatment in the treatment group. The 7-day total effective rate, the length of ICU stay and 28-day mortality were compared between the two groups. Results Compared with before treatment, CI and MAP in the treatment group were significantly increased after treatment [CI (mL·s-1·m-2): 53.34±16.67 vs. 35.01±13.34, MAP (mmHg, 1 mmHg = 0.133 kPa): 72.6±10.6 vs. 62.5±10.3, both P < 0.05], GEDVI, EVLWI, SVRI, CVP were significantly decreased [GEDVI (mL/m2): 760.3±90.2 vs. 960.2±110.3, EVLWI (mL/kg): 6.5±1.3 vs. 12.5±6.2, SVRI (kPa·s·L-1·m-2): 297.3±35.1 vs. 434.1±58.8, CVP (mmHg): 10.1±2.6 vs. 12.2±3.4, all P < 0.05]. Compared with the control group, the 7-day total effective rate of the treatment group was significantly higher (90.0% vs. 80.0%), the length of ICU stay was significantly shorter (days: 8.2±4.5 vs. 10.3±2.5), and the 28-day mortality was significantly lower, with statistically significant difference (all P < 0.05). Conclusion PiCCO monitoring is a goal-oriented treatment management for patients with severe heart failure, which is helpful to individualized accurate treatment, shorten the length of ICU stay and improve short-term prognosis.

7.
Chinese Journal of Medical Education Research ; (12): 469-471, 2019.
Article in Chinese | WPRIM | ID: wpr-753399

ABSTRACT

The theories of pathophysiology come from experimental research,and experimental teaching is an important part of pathophysiology course.Experimental teaching can cultivate the abilities of independent thinking and comprehensive analysis in students,improve their practical skills,and enhance their understanding and application of theoretical knowledge.However,teaching reform should be carried out due to the drawbacks of current pathophysiological experimental teaching.With the teaching idea centered on learning,the quality of pathophysiological experimental teaching can be enhanced by rational arrangement of experimental courses,optimization of teaching contents,and comprehensive application of various teaching models,so as to effectively improve the level of theoretical knowledge and comprehensive practical ability among students.

8.
Chinese Journal of Medical Education Research ; (12): 152-155, 2019.
Article in Chinese | WPRIM | ID: wpr-744144

ABSTRACT

Pathophysiology is a subject that studies the occurrence,development and mechanism of diseases.It plays important roles in medical education and is an important and difficult point in medical education.Based on our teaching experience and the characteristics of pathophysiology,this paper puts forward the idea of “Focus on learning”,aiming to resolve the problems of insufficient communication,unsound teaching design and single teaching method,etc.existed in teaching process.The active communication with students,a good job of teaching design and the reasonable application of various teaching methods and techniques should be carried out to improve the teaching effect of pathophysiology.

9.
Chinese Journal of Cardiology ; (12): 450-457, 2018.
Article in Chinese | WPRIM | ID: wpr-810007

ABSTRACT

Objective@#To explore the effect of microRNA-21 (miR-21) on myocardial fibrosis in mice with chronic viral myocarditis (CVMC) and related mechanisms.@*Methods@#Forty 4-week-old Balb/c male mice were randomly divided into 4 groups (n=10 each): phosphate buffer saline (PBS) group, CVMC group, CVMC+miR-21 inhibitor group, CVMC+isotype control group. The first injection of Coxsackie virus B3 (CVB3) or PBS was performed on day 0, and the total study time was 42 days. Each mouse in CVMC group, CVMC+miR-21 inhibitor group and CVMC+isotype control group was intraperitoneally (i.p) injected with 100TCID50 CVB3 0.1, 0.15, and 0.2 ml on day 0, 14, and 28, respectively. The mice in PBS group were i.p injected with the same dose of PBS at the same time point. After the initial infection, each mouse in CVMC+miR-21 inhibitor group and CVMC+isotype control group was intravenously injected with 0.1 ml miR-21 inhibitor or 0.1 ml isotype control, on day 14 and 28. Cardiac function was measured on surviving mice of 4 groups by echocardiography on day 42. Then, the hearts were removed aseptically to observe the expressions of green fluorescence protein (GFP). The myocardial pathological changes were examined with HE, Masson staining and the myocardial pathological scores (PS), the collagen volume fraction (CVF) were calculated respectively. The levels of miR-21, collagen typeⅠ-A1 (COL1-A1) and collagen type Ⅲ-A1 (COL3-A1) mRNA in heart were detected by quantitative real-time polymerase chain reaction (RT-qPCR). Furthermore, the expressions of transforming growth factor-β1 (TGF-β1) and mothers against decapentaplegic homolog 7(Smad7) in heart were determined with Western blot assay.@*Results@#(1) Cardiac function in 4 groups: Compared with PBS group, left ventricular end systolic diameter (LVESD) and left ventricular end diastolic diameter (LVEDD) were markedly increased in CVMC group and CVMC+isotype control group (all P<0.05), whereas the left ventricular ejection fraction (LVEF) was decreased (P<0.05). LVESD and LVEDD were significantly decreased, and LVEF was increased in CVMC+miR-21 inhibitor group compared with those in CVMC group and CVMC+isotype control group (all P<0.05). (2) Myocardial pathological changes: The expressions of GFP in CVMC+miR-21 inhibitor group and CVMC+isotype control group were visible in heart tissues frozen sections. The hearts in CVMC group and CVMC+isotype control group were enlarged and stiff, inflammatory cells were visible and significantly increased myocardial fibrosis was evidenced in mice of these two groups. Higher PS and CVF were evidenced in CVMC group (PS: 1.14±0.69 vs. 0, CVF: (17.86±2.61)% vs. (5.70±1.42)%, all P<0.05) and CVMC+isotype control group(PS: 1.00±0.63 vs. 0, CVF: (16.78±2.58)% vs. (5.70±1.42)%, all P<0.05) compared to PBS group. Compared with CVMC group and CVMC+isotype control group, degree of cardiac fibrosis was reduced in mice of CVMC+miR-21 inhibitor group (CVF: (11.01±2.55)% vs. (17.86±2.61)%, (11.01±2.55)% vs. (16.78±2.58)%, all P<0.05), whereas PS were similar between them (PS: 0.89±0.60 vs. 1.14±0.69, 0.89±0.60 vs. 1.00±0.63, all P>0.05). (3) Cardiac expressions of miR-21, COL1-A1 and COL3-A1 mRNA: The cardiac expressions of miR-21, COL1-A1 mRNA, COL3-A1mRNA in CVMC group and CVMC+isotype control group were markedly higher than those in PBS group (all P<0.05), which were significantly downregulated in CVMC+miR-21 inhibitor group (all P<0.05 vs. CVMC group and CVMC+isotype control group). (4) The cardiac expressions of TGF-β1 and Smad7 protein: The cardiac expressions of TGF-β1 protein in CVMC group and CVMC+isotype control group were markedly higher, whereas the cardiac Smad7 protein expressions were significantly lower (all P<0.05) than those in PBS group (all P<0.05), these changes could be reversed in CVMC+miR-21 inhibitor group (P<0.05 vs. CVMC group and CVMC+isotype control group).@*Conclusions@#Our results suggest that miR-21 contributes to the myocardial fibrosis in CVMC mice through modulating TGF-β1/Smad7 signaling pathway.

10.
Chongqing Medicine ; (36): 2401-2403, 2014.
Article in Chinese | WPRIM | ID: wpr-453069

ABSTRACT

Objective To establish a simple ,low cost and stable method to detect right ventricular pressure in mice .Methods A PE-50 duct length 15 cm(outside diameter :0 .9 mm ,inner diameter :0 .5 mm) was bent on one terminal and the other terminal was inserted into a 7# syringe needle to connect to a pressure transducer .This duct was intubated into right ventricle via right external jugular vein to detect right ventricular pressure in 80 SPF grade male C57BL/6 mice .Successful cases and operation time were re-corded .Besides ,40 SPF grade male C57BL/6 mice were randomized into the control group (n=20) and chronic hyperbaric hypoxia group(n= 20) .Mice in chronic hyperbaric group were raised in a hyperbaric chamber of simulated 5 000 m high altitude for 4 weeks .The control group was raised outside the chamber simultaneously .Right ventricular systolic pressure was detected with the PE duct .Left and right ventricles were detached and weighed ,and Hermann-Willson index was calculated .Results With this PE duct ,right ventricular intubation success rate was 90% (72/80) ,the operation cost approximately 3 to 5 min each mouse from the separation of blood vessels to detect the time needed for the right ventricle waveform .right ventricular systolic pressure[(39 .52 ± 4 .34 )mm Hg] and Hermann-Willson index(0 .356 ± 0 .039)of chronic hyperbaric hypoxia group were significantly higher than that of control group [(21 .24 ± 2 .7)mm Hg and (0 .256 ± 0 .020)] ,which has significant positive correlation (P<0 .01) .Conclusion It is simple ,fast ,stable ,costing low and of high success ratio to detect right ventricular pressure with this method .

11.
Chinese Journal of Medical Instrumentation ; (6): 250-254, 2010.
Article in Chinese | WPRIM | ID: wpr-281110

ABSTRACT

This paper provides a new design of 12-element array ultrasound transducer. By modeling the beam field model of single element and array and comparing simulated and real ultrasound beam field test data, it can be demonstrated that 12-element array ultrasound transducer has a much better field performance than the 8-element transducer.


Subject(s)
Equipment Design , Ultrasonography, Doppler , Ultrasonography, Prenatal
SELECTION OF CITATIONS
SEARCH DETAIL